<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-17 09-22-22
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 70 kHz 13077 5,8729
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,1 dBr 4,58 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 70 kHz MIN: 17 kHz % above 76 kHz: 5,8729 Acquired: 2025/06/17 9.21.18 Total samples: 13077 Equivalent time: 0:10:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 5,6 dBr MIN: 3,1 dBr AVE: 4,58 dBr % above 12,2 dBr: 0,0 Last value: 5,3 dBr (2025/06/17 9.21.17) 09.08 09.10 09.12 09.14 09.16 09.18 09.20 0 2 4 6 Pm [dBr]